利用太阳能光伏板将太阳能转化为处理污水用的电能,蓄电池充足了电以后,即使连续7天阴雨,也能保证污水处理正常运行。
The solar photovoltaic panel is used to convert solar energy into electric energy for sewage treatment. After the battery is fully charged, the normal operation of sewage treatment can be guaranteed even if it is cloudy and rainy for 7 consecutive days.
该系统经过管道收集污水、厌氧生物处理、接触氧化、沉淀、达标排放等多道程序后,原本浑浊的污水就变得非常清澈。
After pipeline collection of sewage, anaerobic biological treatment, contact oxidation, sedimentation, standard discharge and other procedures, the originally turbid sewage becomes very clear.
太阳能光伏电池。采用单晶硅或多晶硅电池,电池zui大输出功率不小于600W,功率误差要求在±3%以内;电池光电转换率大于16%;电池输出功率在10年内大于90%,25年内大于80%;正常使用情况下,产品寿命要求大于20年。
Solar photovoltaic cells. Monocrystalline silicon or polycrystalline silicon battery shall be adopted, with battery Zui large output power not less than 600W and power error within ± 3%; The photoelectric conversion rate of the battery is greater than 16%; The output power of the battery is more than 90% within 10 years and more than 80% within 25 years; Under normal use, the service life of the product shall be more than 20 years.
蓄电池。设备蓄电池要求配备太阳能蓄电池;蓄电池容量不小于1200AH,能满足系统在7天连续阴雨天运行要求;蓄电池使用寿命不低于6年。
Battery. The equipment battery shall be equipped with solar battery; The capacity of storage battery shall not be less than 1200ah, which can meet the requirements of system operation in 7 consecutive rainy days; The service life of the battery shall not be less than 6 years.
曝气系统。设备曝气量要求每小时不低于8.0m3,每天曝气量不小于160m3;曝气压力能满足在水下2.5米处工作要求。
Aeration system. The aeration capacity of the equipment shall not be less than 8.0m3 per hour and 160m3 per day; The aeration pressure can meet the working requirements at 2.5m underwater.
设备控制系统。对蓄电池的过充和过放有保护功能,有热补偿功能;对光伏板有防止逆流放电功能;对逆变器有保护及自动重启功能;对负载有保护及智能分配功能;
Equipment control system. It has protection function and thermal compensation function for overcharge and discharge of battery; It has the function of preventing reverse current discharge for photovoltaic panels; It has the functions of protection and automatic restart for the inverter; It has the functions of load protection and intelligent distribution;
通讯和管理。设备有远程通讯功能,具备自我故障诊断并及时远程报警功能;每日运行情况自动回复功能;远程控制功能等。
Communication and management. The equipment has remote communication function, self fault diagnosis and timely remote alarm function; Automatic reply function of daily operation; Remote control function, etc.
电话:0571-81671995
传真:0571-81671995